- 主题:说一下K宝A瓶检测报告两个值的含义
10ng/ml是MRPL,属于衡量指定实验室测试能力水平的值。实验室测定曲美他嗪的方法检测限必须低于10ng/ml。
那2.1ng/ml的A瓶实测值是可以说的通了。
“The MRPL is the minimum concentration of a Non-Threshold Substance or a Metabolite or Marker of a
Non-Threshold Substance that Laboratories shall be able to detect (Initial Testing Procedure) and
identify (Confirmation Procedure) in routine operations.
o The MRPL is not a Threshold (T) nor is it a Limit of Detection (LOD). Adverse Analytical Findings
(AAFs) may result from concentrations below the established MRPL values;”
对于曲美他嗪,应该是属于Non-threshold substance(这部分我理解为检出即阳性,没有cut off level,未进行确认)
WADA鼓励各个实验室把这类物质的检测浓度水平搞得越低越好。
"[Comment: It is recognized that some Laboratories will be able to identify and report these Non-Threshold Substances in lower concentrations than other Laboratories. While such individual capabilities are encouraged in order to improve the overall system, it is also recognized that there are minimum routine detection capabilities (defined by the applicable MRPLs) at which all Laboratories shall operate.] "
所以,美帝就是用技术霸权(最顶流的分析仪器全是美帝的)搞别人。(说不定大鹅那边实验室压根检不出美帝的低浓度样品)
修订一下,俄罗斯没有WADA资质实验室。。。。。呵呵呵。。。。
https://www.wada-ama.org/sites/default/files/resources/files/td2022mrpl_v1.0_final_eng.pdf
--
修改:cryingleaf FROM 101.95.128.*
FROM 101.95.128.*
查了一下,俄罗斯甚至没有有资质的实验室。。。。
明着搞你
中国买美帝的高端设备搞反兴奋剂估计也花了9位数了
【 在 zxf 的大作中提到: 】
: 这规定很搞笑吧,把阳性标准订成检出即阳性,实验室资质定得宽宽松松。那想搞死谁就找一台精密仪器,想通融就找一台老旧仪器。
:
--
FROM 101.95.128.*
无论怎么样,这个检测目标已经卷到极致了,2018年的论文说口服15mg,11天半之后的尿样还能测出来,检测限低于0.02ng/ml。如果K宝A瓶真的检出2.1ng/ml,感觉在仪器中是一个巨大的,远高于背景的响应了。
An oral dose of 15 mg was administered to 10 male volunteers, after which urine samples collected during the following 276 hours were analyzed using the developed method, allowing for examination of the target analytes' excretion profile. The limit of detection of all target analytes was <0.02 ng/mL.
PMID: 30240154 DOI: 10.1002/dta.2504
【 在 sm2015 的大作中提到: 】
: 俄罗斯是都被取消资质了
:
: 单剂口服曲美他嗪20毫克后,血浆峰浓度约为55ng/ml,曲美他嗪半衰期大约6小时,意思是说过6小时剩1/2,12小时剩1/4,18小时剩1/8,24小时剩1/16,一般认为5-6个半衰期基本清除完毕
: ...................
--
FROM 101.95.128.*
无效。但是能说明理论上能测到很低很低。。。
【 在 maoxiong03 的大作中提到: 】
: 这种有效吗? 发个论文说能检测就行?
:
: 【 在 cryingleaf 的大作中提到: 】
: ...................
--来自微水木3.5.11
--
FROM 101.82.59.*
所以现在都用高分辨质谱,扫描各种异常(未知)物质
【 在 BBK 的大作中提到: 】
: 回头再发明一种药,能中和这个药的残留……
:
: 【 在 aquarion (小日向光 新之闪光) 的大作中提到: 】
: ...................
--来自微水木3.5.11
--
FROM 27.115.21.*